带钢端头的装配式混凝土梁柱中节点滞回性能试验研究

戎贤1,2,杨洪渭1,张健新1,2   

  1. (1. 河北工业大学 土木与交通学院,天津 300401; 2. 河北省土木工程技术研究中心,天津 300401)
  • 收稿日期:2019-06-10 修回日期:2020-12-18 出版日期:2021-02-16 发布日期:2021-02-16
  • 作者简介:戎贤(1965—),男,河北定州人,教授,博士,博士生导师,主要从事结构抗震研究。E-mail:xrong@hebut.edu.cn 通信作者:张健新(1986—),女,河北唐山人,博士,主要从事结构抗震研究。E-mail:zhangjianxin505@126.com
  • 基金资助:
    河北省自然科学基金项目(E2018202290、E2017202278);天津市建委科技项目(HE1863)

Experimental Research on Hysteresis Behavior of Prefabricated Concrete Beam-Column Joint with Steel End Connector

RONG Xian1, 2, YANG Hongwei1, ZHANG Jianxin1, 2   

  1. (1. School of Civil and Transportation Engineering, Hebei University of Technology, Tianjin 300401, China; 2. Civil Engineering Technology Research Center of Hebei Province, Tianjin 300401, China)
  • Received:2019-06-10 Revised:2020-12-18 Online:2021-02-16 Published:2021-02-16

摘要: 为解决装配式混凝土梁柱中节点连接复杂的问题,提出采用钢端头进行连接。设计了3个带钢端头连接的装配式混凝土梁柱中节点ZGJ-1、ZGJ-2和ZGJ-3,开展了低周反复荷载试验,研究了水平连接板间腹板的设置及伸入预制梁内钢端头的长度对中节点滞回性能的影响。结果表明:带钢端头的新型装配式混凝土梁柱中节点抗震性能良好;伸入预制梁内钢端头的长度对中节点性能影响不大;水平连接板间设置腹板能较大程度提高中节点的抗震性能。

关键词: 桥梁工程, 装配式梁柱中节点, 滞回性能, 拟静力试验

Abstract: To solve the problem of the complicated connection of prefabricated concrete beam-column joints, the connection with steel end connector was proposed. Three prefabricated concrete beam-column joints with steel end connector, named ZGJ-1, ZGJ-2 and ZGJ-3, were designed. Through the low-cycle cyclic loading test, the influence of the web setting between the horizontal connecting plates and the length of the steel end extending into the precast beam on the hysteretic behavior of the joint was studied. The test results show that the new type of prefabricated concrete beam-column joints with steel end connector has good seismic behavior. The length of the steel end connector extending into the precast beam has little influence on the performance of the joints, and the setting of the web between the horizontal connecting plates can greatly improve the seismic behavior of the joints.

Key words: bridge engineering, fabricated beam-column joint, hysteresis behavior, quasi-static test